Question: What is COP and EER?

The terms COP (coefficient of performance) and EER (energy efficiency ratio) describe the heating and cooling efficiency of air conditioners. They indicate the ratio of heating or cooling provided by a unit relative to the amount of electrical input required to generate it.

What does EER and COP mean?

An air conditioners efficiency is measured using the Energy Efficiency Ratio (EER) for cooling and Coefficient of Performance (COP) for heating. They indicate the ratio of cooling or heating provided by a unit relative to the amount of electrical input required to generate it.

What is COP in energy?

COP stands for Coefficient Of Performance and indicates the efficiency of heating and cooling machines. The COP is defined by the ratio heat dissipation and electrical power intake. Its like the efficiency of the machine, but higher than 100%.

What is COP formula?

COP = |Q| W. COP is defined as the relationship between the power (kW) that is drawn out of the heat pump as cooling or heat, and the power (kW) that is supplied to the compressor.

How are EER COPs calculated?

Cooling Load - Convert kW/ton to COP or EERkW/ton = 12 / EER.kW/ton = 12 / (COP x 3.412)COP = EER / 3.412.COP = 12 / (kW/ton) / 3.412.EER = 12 / (kW/ton)EER = COP x 3.412.

Is a higher or lower COP better?

The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs.

What is a good energy efficiency ratio EER?

12 Generally, an EER of 12 or above is considered energy efficient, however, when comparing two models, the one with the higher EER is more energy efficient regardless of whether or not it is above 12.

Is a higher COP better?

The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs.

Can COPs be less than1?

Coefficient Of Performance (COP) is the ratio of Coldness produced to the Heat or Work supplied. COP can be less than 1. Usually,COP is more than 1 for VCRS which is actually desirable since VCRS uses high grade electrical energy as the energy input!!...

Is a high COP good or bad?

Air source heat pumps tend to be less efficient, and a COP over 3 is considered good. Comparing different air source heat pumps, it is worth bearing in mind that a heat pump with a higher CoP / SPF will cost more, and the same is true when comparing ground source heat pumps with one another.

What is a good COP value?

That means that in 100% ideal case the maximum COP is 8.8. But in practice, its lower. In fact, the highest COP a heat pump can achieve is about 4.5. Any heat pump with a COP of above 3 has a very high energy-efficiency.

Why can COP be greater than 1?

Why the value of the COP of the refrigeration system is always greater than 1? The COP usually exceeds 1, especially in heat pumps, because, instead of just converting work to heat (which, if 100% efficient, would be a COP of 1), it pumps additional heat from a heat source to where the heat is required.

What is a good EER?

12 12 EER rating is an excellent energy-efficiency rating for an air conditioner. Some of the best devices can even reach more than 12 EER. The best mini split air conditioners have an extremely high 12+ EER rating (check them here).

What is EER formula?

EER = 389.2 - 41.2*age (years) + PAL * (15 * weight (kg) + 701.6 * height (m)), where PAL = 1 if sedentary, 1.18 if low active, 1.35 if active, and 1.60 if very active.

What is EER used for?

The EER is based on calculations that account for an individuals energy intake, energy expenditure, age, sex, weight, height, and physical activity level. Including physical activity level in the calculations makes determining energy expenditure possible and achieving energy balance a more realistic goal.

Can a COP be less than 1?

COP(L) may be less than 1, but COP(H) is theoretically always greater than 1 (in some special cases COP(H) may be less than 1 due to heat losses in experimental systems).